loader

project

Customized 70m³ Per Hour Industrial RO Water System For Dairy Enterprise;


ge whole house water filter


Customer is local Dairy factory Shibu Dairy Group. water quality is crucial for dairy production to ensure the health of cows and the safety of milk and dairy products. Customer required pH Level,Total Dissolved Solids TDS, Hardness, Alkalinity, Nitrate-Nitrogen,Sulfates reach to an ideal data. JuJinRO base on the raw water condition, customized a 70m³ per hour RO water system reverse osmosis water for plants.
The system uses a multi-media filter + RO process to ensure that the system produces stable and qualified boiler water and production water for dairy enterprises replacing reverse osmosis filters.
The process flow is divided into two parts: the pretreatment system and the reverse osmosis system. Selecting an appropriate pretreatment process can reduce fouling, scaling and membrane degradation, thereby greatly improving system performance and optimizing system water output, desalination rate, recovery rate and operating costs.
The reverse osmosis system undertakes the main desalination task and is the key core process of this process ro osmosis water filter changing reverse osmosis filters changing ro filters.

tap water filter machine

Raw Water Condition of countertop reverse osmosis

The raw water is from local tap water, PH level is 6.0 to 8.5. Not in an ideal range, Total Dissolved Solids TDS in a high level which will affect the taste and reduce water intake by cows.Hardness 121-180 ppm is hard,And High alkalinity can affect the taste and have a laxative effect, it Should be less than 500 ppm. Nitrate-Nitrogen: Should be less than 25 ppm to avoid toxicity replacing ro filters.
Sulfates: Should be less than 250 ppm to prevent a salty taste and laxative effects culligan reverse osmosis system
Ammonia-Nitrogen: Should be less than 0.5 ppm reverse osmosis tap commercial reverse osmosis system

pur uv water filter

Our Solutions of water filtration ro filter

✪JuJinRO membrane water filter system configuration list waterdrop reverse osmosis: The reverse osmosis (RO) system uses the principle of reverse natural osmosis to remove most of the dissolved salts in the water, while removing some large molecules and small particles that are not removed by pretreatment. The reverse osmosis system includes a 5mm security filter, a high-pressure pump, a set of RO membrane group, a set of antiscalant dosing equipment and a set of RO cleaning equipment. The RO membrane group is arranged on a stainless steel rack. There are various valves and various display instruments on the body of the complete set of equipment to facilitate on-site maintenance and monitoring by users ro water filter machine.
The water recovery rate of the RO system is above 75%, and the desalination rate of the system is not less than 98% within one year reverse osmosis drinking water filter system.
The reverse osmosis uses a set of reverse osmosis treatment membrane groups with an output of 70m3/h. The desalination rate of a single membrane reaches≥99.5%. The reverse osmosis device is equipped with an on-site control panel, on which various on-site instruments and control buttons are installed osmosis water filtration.
The equipment consists of a main body, a water distribution device, a water collection device, external piping, etc. The water inlet device is a top water inlet and trumpet-type water distribution device, and the water collection device is a water distributor water collection structure; the external piping of the equipment body is equipped with a valve and a pressure sampling interface, which is convenient for users to install on site and realize the normal operation of the device. JuJinRO offer competitive price compare to aquatru water filtration

apec water filtration

✪Operating conditions of reverse osmosis device:
1) Design temperature: 20-25℃ osmose water filter
2) Design total water inflow: 100m3/h osmosis water filter system
3) Design water output: 70m3/h osmosis water filtration system
4) System recovery rate: ≥75% within three years ro water filtration system
5) System desalination rate: ≥98% within one year ro machine

livpure recharge

✪Reverse Osmosis Membrane:
The reverse osmosis device membrane element uses a polyamide composite membrane produced by Wharton. The element is composed of three layers of film composites. The surface layer is made of aromatic polyamide with a thickness of about 2000 angstroms and supported by a layer of microporous polysulfone. It can withstand high pressure and has good resistance to mechanical tension and chemical corrosion. The element has a relatively large water production flux and has a removal rate of more than 99% for NaCl, CaCl2, and MgCl2 reverse osmosis water near me.
The reverse osmosis device is equipped with 70 LP22-8040 membrane elements, with a water production of ≥70m3/h and a recovery rate of ≥75% reverse osmosis machine.

uv filtration system

✪RO pressure membrane tube of ro water filter system:
This RO system is equipped with a set of JuJinRO chemical cleaning equipment, including an anti-corrosive solvent tank, a cleaning filter (5mm safety filter), a cleaning pump and connecting pipes. The flow rate of the chemical cleaning pump is 12m3/h, the head is 0.30MPa, the volume of the chemical tank is 500L, and the flow rate of the safety filter is 12m3/h. Chemical cleaning adopts the method of manual liquid preparation and manual control of the cleaning process reverse osmosis drinking water filter osmosis water filter.

electric water purifier for home

✪System Control & Electrical of reverse osmosis water filtration system:
The control system hardware consists of a set of programmable controller (PLC). According to the characteristics of the system, the process flow is divided into two parts: pretreatment system and reverse osmosis system. PLC is used to realize automatic control of reverse osmosis. The reverse osmosis system can be centrally controlled on site, and can switch between automatic and manual operation modes best ro filter system.
The reverse osmosis system can realize manual and automatic switching. In abnormal operation, each pump equipment and control valve can be manually controlled ultraviolet water purification ro reverse osmosis.
When RO is put into operation, in order to prevent the high-pressure pump from suddenly starting to increase the pressure, causing high-pressure impact on the RO membrane element to damage the reverse osmosis membrane, a slow-opening valve is set between the high-pressure pump outlet of the RO device and the RO membrane assembly. The programmable controller (PLC) controls the valve to open, so that the reverse osmosis membrane element gradually increases the pressure to a certain level whole house ro water filter system best ro water filter system.
When RO is stopped, the RO membrane assembly should be automatically flushed for about 3-5 minutes to prevent the high-concentration salts in the concentrated water from depositing and scaling on the RO membrane surface and affecting the performance of the membrane ro water filtration.

ro carbon filter